Electrical Insulating Mats

MITC is providing "ISI Marked" Electrical Insulating Mats. These insulating mats are used for safety of workers while installing and operating electrical equipment because of possibility of leakage of current.

Electrical Insulating Mats - ISI Marked IS:15652

Request Callback

₹ 500 / Meter Get Latest Price

Product Brochure
Thickness Range2mm,2.5mm and 3mm
Thickness2mm,2.5mm and 3mm
MaterialPVC & Synthethic Rubber (IS 156522006)
TypeConforming to IS 156522006
Mat Size1 Meter Wide x Runnling Length (Max. 10 Meters)
Usage/ApplicationThe Mat can be used in Indoor and outdoor locations and are mostly used in front and rear side side
LengthAs per order (Standard 10 Meters)
Minimum Thickness2mm
Packaging TypeRoll Form
ShapeRectangular

Minimum order quantity: 10 Meter

Item Code: IS-15652-2006

Voltage Ratings:


  • Class Thickness Grade KV Proof voltage B/Down voltage
  • A 2.0 mm 3.3 10KV/3 minutes 30 KV
  • B 2.5 mm 11 22KV/3 minutes 45 KV
  • C 3.0 mm 33 36KV/3 minutes 65 KV

Construction:

Made from Highly Electrical resistant Elastomers, free from any insertions (includes rubbers, latex and Elastomeric compound that may be natural or synthetic or a mixture or a combination of both)

Surface: Upper surface of the mat is having small anti-skid aberration marks (rough surface, without edges) to avoid slippery effects and lower surface is plain.

Dimensions: Sizes are 1mtr x 2mtr or long length and thickness as per classification & designation

Working Temp: -10 to 55°C

Typical Features:

  • Confirming IS: 15652/2006 (Latest), ISI marked.
  • High Die Electric Strength Up to 65 KV.
  • Insulation Resistance Up to 1494000 Mega Ohm.
  • Fire Retardant.
  • Good Mechanical Properties to with Stand Load and Movement of Breaker Trolleys and Associated Electrical Equipment including heavy foot traffic.
  • No Adverse Effect of Acids, Alkalis and Transformer Oil.
  • Manufactured Without Any Metallic Derivatives
  • Suitable For Both A.C & D.C Electrical Installations
  • Easy To Install, Can Be Pasted.
  • Water And Moisture Proof, Does Not Decay.
  • High Tensile Strength and Elongation Properties.

Application:

Safety from electrical shock is required for workmen whether they are involved in electricity generation, transmission, distribution or its use. These mats are highly recommended for total safety of workmen from electrical shock when working in or around environment like:

  • High Voltage Panels
  • Sub-station
  • Power Transformer Rooms
  • LT & HT Labs
  • Near Bus bars
  • Near Control Panels etc.

Shockproof Rubber Mat

Request Callback

₹ 100 / Meter Get Latest Price

Product Brochure
Mat Size1 Meter Wide X Running Length
TypeElectrical Floor Mats
MaterialPVC Rubber
PatternCoin, Dotted
Usage/ApplicationFor Electrical Pumps, Switchboard, Panel Romms
Packaging Type1 Meter Wide X 10 Meter Long in roll form
Thickness3 mm
Country of OriginMade in India

Minimum order quantity: 1 Meter

Item Code: IS-15652-2006

Voltage Ratings:


  • Class Thickness Grade KV Proof voltage B/Down voltage
  • A 2.0 mm 3.3 10KV/3 minutes 30 KV
  • B 2.5 mm 11 22KV/3 minutes 45 KV
  • C 3.0 mm 33 36KV/3 minutes 65 KV

Construction:

Made from Highly Electrical resistant Elastomers, free from any insertions (includes rubbers, latex and Elastomeric compound that may be natural or synthetic or a mixture or a combination of both)

Surface: Upper surface of the mat is having small anti-skid aberration marks (rough surface, without edges) to avoid slippery effects and lower surface is plain.

Dimensions: Sizes are 1mtr x 2mtr or long length and thickness as per classification & designation

Working Temp: -10 to 55°C

Typical Features:

  • Confirming IS: 15652/2006 (Latest), ISI marked.
  • High Die Electric Strength Up to 65 KV.
  • Insulation Resistance Up to 1494000 Mega Ohm.
  • Fire Retardant.
  • Good Mechanical Properties to with Stand Load and Movement of Breaker Trolleys and Associated Electrical Equipment including heavy foot traffic.
  • No Adverse Effect of Acids, Alkalis and Transformer Oil.
  • Manufactured Without Any Metallic Derivatives
  • Suitable For Both A.C & D.C Electrical Installations
  • Easy To Install, Can Be Pasted.
  • Water And Moisture Proof, Does Not Decay.
  • High Tensile Strength and Elongation Properties.

Application:

Safety from electrical shock is required for workmen whether they are involved in electricity generation, transmission, distribution or its use. These mats are highly recommended for total safety of workmen from electrical shock when working in or around environment like:

  • High Voltage Panels
  • Sub-station
  • Power Transformer Rooms
  • LT & HT Labs
  • Near Bus bars
  • Near Control Panels etc.

Shockproof Insulation Mat

Request Callback

₹ 100 / Meter Get Latest Price

Product Brochure
Thickness2 mm
Voltage3.3 KV
MaterialPVC
Size1 Meter
Usage/ApplicationFor electrical room
Country of OriginMade in India

Minimum order quantity: 1 Meter

Item Code: IS-15652-2006

Voltage Ratings:


  • Class Thickness Grade KV Proof voltage B/Down voltage
  • A 2.0 mm 3.3 10KV/3 minutes 30 KV
  • B 2.5 mm 11 22KV/3 minutes 45 KV
  • C 3.0 mm 33 36KV/3 minutes 65 KV

Construction:

Made from Highly Electrical resistant Elastomers, free from any insertions (includes rubbers, latex and Elastomeric compound that may be natural or synthetic or a mixture or a combination of both)

Surface: Upper surface of the mat is having small anti-skid aberration marks (rough surface, without edges) to avoid slippery effects and lower surface is plain.

Dimensions: Sizes are 1mtr x 2mtr or long length and thickness as per classification & designation

Working Temp: -10 to 55°C

Typical Features:

  • Confirming IS: 15652/2006 (Latest), ISI marked.
  • High Die Electric Strength Up to 65 KV.
  • Insulation Resistance Up to 1494000 Mega Ohm.
  • Fire Retardant.
  • Good Mechanical Properties to with Stand Load and Movement of Breaker Trolleys and Associated Electrical Equipment including heavy foot traffic.
  • No Adverse Effect of Acids, Alkalis and Transformer Oil.
  • Manufactured Without Any Metallic Derivatives
  • Suitable For Both A.C & D.C Electrical Installations
  • Easy To Install, Can Be Pasted.
  • Water And Moisture Proof, Does Not Decay.
  • High Tensile Strength and Elongation Properties.

Application:

Safety from electrical shock is required for workmen whether they are involved in electricity generation, transmission, distribution or its use. These mats are highly recommended for total safety of workmen from electrical shock when working in or around environment like:

  • High Voltage Panels
  • Sub-station
  • Power Transformer Rooms
  • LT & HT Labs
  • Near Bus bars
  • Near Control Panels etc.

IEC 61111 Insulating Mats

Request Callback

₹ 600 / Meter Get Latest Price

Product Brochure
ThicknessThickness - As Per Specified Class
Mat Size0.9/1/1.2 Meter Wide x Length - 2mtr,5mtr,10mtr,20mtr,or as per requirement
Voltage11 KV
MaterialRubber elastomer*,Anti Skid Finish. Macromolecular material
ColorBlack,Blue,Grey
PatternAnti-Skid Texture Finish
High Electrical Insulation ResistanceUpto 36 Kv
Usage/ApplicationThe Mat can be used in Indoor and outdoor locations and are mostly used in front and rear side side.
Max Withstanding TemperatureFlame shall not reach any point on a 50mm circle.
Application/UsageThe Mat can be used in Indoor and outdoor locations and are mostly used in front and rear side side.

Minimum order quantity: 50 Meter

Insulating Matting (Di-Electric Carpets) made of Rubber Compound suitable for providing the Electrical safety to the workmen working around the possible areas of Electrical shock and act as a safeguard equipment from electrical shock due to leakage of current, shot circuit or any other. The special high quality Rubber Compound ensures the complete shock protection against electrical shocks due to electrical earth faults.

Our Mats are fully compliant With IEC 61111 (International Electro Technical Commission) and are regularly tested by third like TUV, Lloyds and many others. The mats offered by us are ROHS and PAH Compliant.

Features And Advantages
  • Fully tested to specification IEC 61111.
  • Provides safety for operators against electrical shock.
  • High Electrical Resistance Up to 50 KV/50000 volts.
  • Suitable for both AC and DC Applications.
  • Health and safety regulation Halogen Free flame retardant material.
  • Highly Flexible mats with self-gripping design on floor.
  • Anti-Fatigue type. Comfortable while standing for long period.
  • Anti-Slip Finish. Tested to slip resist test.
  • Resistant to acid, oil and Low temperature test.
  • Ozone, UV and weather resistant.
  • Permanent Marking-Durable and un-erasable done while curing of mats.
  • Fully Traceable supply.
  • Low Maintainance.
  • No Recycled Rubber.
ClassStandard ThicknessMax. Use VoltageProof VoltageWithstand VoltageColor Code
0 3 mm 1000 Volts 5000 Volts 10000 Volts Red
1 3 mm 7500 Volts 10000 Volts 20000 Volts White
2 3/6 mm 17000 Volts 20000 Volts 30000 Volts Yellow
3 4/6 mm 26500 Volts 30000 Volts 40000 Volts Green
4 4/6 mm 36000 Volts 40000 Volts 50000 Volts Orange

 

Dimensions
Width 0.9mtr, 1.0mtr, 1.2mtr
Length 2mtr, 5mtr, 10mtr, 20mtr, or as per requirement
Thickness As Per Specified Class
Colors Black, Blue, Grey
Surface/Design Anti-Skid Texture Finish

Note: Other colors also available on request.

Other Properties
S.No.Technical SpecificationAll Classes
1 Composition and Surface Rubber elastomer*, Anti Skid Finish. Macromolecular material which returns rapidly to its final dimension by a weak stress and release of the stress.
2 Workmanship Mats shall be free from Harmful physical irregularities.
3 Mechanical Puncture Resistance Min. 70N
4 Slip Resistance Test @ force of 70N Maximum 15mm
5 Ageing Test at 70 deg cl./168hrs. Puncture Resistance shall be min. 80% of original value.
6 Flame Retardant Test Flame shall not reach any point on a 50mm circle.
7 Thermal Test (Low Temp. Test) No Crack@100N.
No-Breakdown on specified voltage.
8 Acid Test; H2SO4 For 8hrs. Minimum Retention in Mech. Puncture Test initial value. Min. 75% Retention & No Breakdown on specified Voltage.
9 Oil Test; oil for 2hrs.
Minimum Retention in Mech. Puncture test initial value.
Min. 75% Retention & No Breakdown on specified Voltage.

ASTM-D-178 Insulating Mats

Request Callback

₹ 600 / Meter Get Latest Price

Product Brochure
Thickness Range3.2mm to,3.2mm to 12.7mm
Thickness6 mm
Voltage11 KV
PatternPlain
MaterialRubber
FeaturesShock Proof
Dielectric StrengthUp-to 50 Kv
Height1 / 1.2 Meter
Minimum Thickness3.2mm
Packaging TypeRoll Form

Minimum order quantity: 10 Meter

We deliver rubber insulating mattings that are designed according to the ASTM-D-178 Standard. This standard is set by the American Society for Testing and Materials. The ASTM-D-178 Standard endorses a thickness of 3.2mm to 12.7mm for these particular mattings. It depends upon the smooth lower surface with the usage/working voltage resistance & antiskid textured surface on the top. Such safety rubber mattings (Type-1 Grade) are moisture, water & leakage proof that guarantee a long functional (work) life. A Type-2 Grade Insulating Mat contains certain additional properties such as Flame & Ozone resistance.

 


Product Code

Class

Recommended Thickness

Max Use/Working Voltage

AC Proof Voltage

Di-electric strength (Withstand Voltage)

Approx. Weight Per Sqr Mtr.

ASTM 001

0

3.2 mm

1.0 KV

5.0 KV

6.0 KV

5.0 Kgs

ASTM 002

1

4.8 mm

7.5 KV

10.0 KV

20.0 KV

7.5 Kgs

ASTM 003

2

6.4 mm

17.0 KV

20.0 KV

30.0 KV

10.0 Kgs

ASTM 004

3

9.5 mm

26.5 KV

30.0 KV

40.0 KV

15.0 Kgs

ASTM 005

4

12.7 mm

36.0 KV

40.0 KV

50.0 KV

20.0 Kgs

ASTM CD (Custom)

-

Upto 25.0 mm

Upto 36.0 KV

Upto 40.0 KV

Upto 50.0 KV

-

 

Sl No.

Features

Values

1

Standard Size & Design

1) 1.0 Mtr. Wide x 10.0 Mtr. Long. in Texture Design.

2) 1.2 Mtr. Wide x 10.0 Mtr. Long. in Texture Design

2

Custom Size & Design

Max. width upto 2400mm, length upto 20M and thickness upto 25mm available in Texture Design only

3

Standard Colour

Black & Blue without Metallic Derivatives. (Other colours available on request subject to availability.)

4

Manufacturing Tolerance

±10% on thickness, ±5% on length, ±2% on width

5

Type

Unless specified, insulating matting shall be supplied as per Type I grade. Also available on request, Type II grade (A-Ozone Resistance, B-Flame Resistance, C-Oil Resistance) with combination of all three or individual properties.

 

Standard Size & Design

1.0 Mtr Wide x 10.0 Mtr Long in Textured Design

Standard Colour

Black & Blue without Metallic Derivatives (Other colours available on request subject to availability)

Insulating Rubber Mats Isi Mark

Request Callback

₹ 100 / Meter Get Latest Price

Product Brochure
Thickness2mm
Usage/ApplicationElectrical Insulation
ColorBlack
BrandMITC
MaterialPVC Synthetic Elastomer
Country of OriginMade in India

Minimum order quantity: 2 Meter

Item Code: IS-15652-2006

Voltage Ratings:


  • Class Thickness Grade KV Proof voltage B/Down voltage
  • A 2.0 mm 3.3 10KV/3 minutes 30 KV
  • B 2.5 mm 11 22KV/3 minutes 45 KV
  • C 3.0 mm 33 36KV/3 minutes 65 KV

Construction:

Made from Highly Electrical resistant Elastomers, free from any insertions (includes rubbers, latex and Elastomeric compound that may be natural or synthetic or a mixture or a combination of both)

Surface: Upper surface of the mat is having small anti-skid aberration marks (rough surface, without edges) to avoid slippery effects and lower surface is plain.

Dimensions: Sizes are 1mtr x 2mtr or long length and thickness as per classification & designation

Working Temp: -10 to 55°C

Typical Features:

  • Confirming IS: 15652/2006 (Latest), ISI marked.
  • High Die Electric Strength Up to 65 KV.
  • Insulation Resistance Up to 1494000 Mega Ohm.
  • Fire Retardant.
  • Good Mechanical Properties to with Stand Load and Movement of Breaker Trolleys and Associated Electrical Equipment including heavy foot traffic.
  • No Adverse Effect of Acids, Alkalis and Transformer Oil.
  • Manufactured Without Any Metallic Derivatives
  • Suitable For Both A.C & D.C Electrical Installations
  • Easy To Install, Can Be Pasted.
  • Water And Moisture Proof, Does Not Decay.
  • High Tensile Strength and Elongation Properties.

Application:

Safety from electrical shock is required for workmen whether they are involved in electricity generation, transmission, distribution or its use. These mats are highly recommended for total safety of workmen from electrical shock when working in or around environment like:

  • High Voltage Panels
  • Sub-station
  • Power Transformer Rooms
  • LT & HT Labs
  • Near Bus bars
  • Near Control Panels etc.

High Voltage Rubber Mat

Request Callback

₹ 100 / Meter Get Latest Price

Product Brochure
Thickness3mm
Usage/ApplicationElectrical Insulation
ColorBlack
PatternCheckered
BrandMITC
MaterialPVC Rubber
Country of OriginMade in India

Minimum order quantity: 1 Meter

Item Code: IS-15652-2006

Voltage Ratings:


  • Class Thickness Grade KV Proof voltage B/Down voltage
  • A 2.0 mm 3.3 10KV/3 minutes 30 KV
  • B 2.5 mm 11 22KV/3 minutes 45 KV
  • C 3.0 mm 33 36KV/3 minutes 65 KV

Construction:

Made from Highly Electrical resistant Elastomers, free from any insertions (includes rubbers, latex and Elastomeric compound that may be natural or synthetic or a mixture or a combination of both)

Surface: Upper surface of the mat is having small anti-skid aberration marks (rough surface, without edges) to avoid slippery effects and lower surface is plain.

Dimensions: Sizes are 1mtr x 2mtr or long length and thickness as per classification & designation

Working Temp: -10 to 55°C

Typical Features:

  • Confirming IS: 15652/2006 (Latest), ISI marked.
  • High Die Electric Strength Up to 65 KV.
  • Insulation Resistance Up to 1494000 Mega Ohm.
  • Fire Retardant.
  • Good Mechanical Properties to with Stand Load and Movement of Breaker Trolleys and Associated Electrical Equipment including heavy foot traffic.
  • No Adverse Effect of Acids, Alkalis and Transformer Oil.
  • Manufactured Without Any Metallic Derivatives
  • Suitable For Both A.C & D.C Electrical Installations
  • Easy To Install, Can Be Pasted.
  • Water And Moisture Proof, Does Not Decay.
  • High Tensile Strength and Elongation Properties.

Application:

Safety from electrical shock is required for workmen whether they are involved in electricity generation, transmission, distribution or its use. These mats are highly recommended for total safety of workmen from electrical shock when working in or around environment like:

  • High Voltage Panels
  • Sub-station
  • Power Transformer Rooms
  • LT & HT Labs
  • Near Bus bars
  • Near Control Panels etc.

High Voltage Insulating Mat

Request Callback

₹ 100 / Meter Get Latest Price

Product Brochure
Thickness3 mm
Voltage33 KV
MaterialPVC
Size1 Meter X 2 to 100 Meter
Usage/ApplicationFor electrical flooring
Country of OriginMade in India

Minimum order quantity: 2 Meter

Item Code: IS-15652-2006

Voltage Ratings:


  • Class Thickness Grade KV Proof voltage B/Down voltage
  • A 2.0 mm 3.3 10KV/3 minutes 30 KV
  • B 2.5 mm 11 22KV/3 minutes 45 KV
  • C 3.0 mm 33 36KV/3 minutes 65 KV

Construction:

Made from Highly Electrical resistant Elastomers, free from any insertions (includes rubbers, latex and Elastomeric compound that may be natural or synthetic or a mixture or a combination of both)

Surface: Upper surface of the mat is having small anti-skid aberration marks (rough surface, without edges) to avoid slippery effects and lower surface is plain.

Dimensions: Sizes are 1mtr x 2mtr or long length and thickness as per classification & designation

Working Temp: -10 to 55°C

Typical Features:

  • Confirming IS: 15652/2006 (Latest), ISI marked.
  • High Die Electric Strength Up to 65 KV.
  • Insulation Resistance Up to 1494000 Mega Ohm.
  • Fire Retardant.
  • Good Mechanical Properties to with Stand Load and Movement of Breaker Trolleys and Associated Electrical Equipment including heavy foot traffic.
  • No Adverse Effect of Acids, Alkalis and Transformer Oil.
  • Manufactured Without Any Metallic Derivatives
  • Suitable For Both A.C & D.C Electrical Installations
  • Easy To Install, Can Be Pasted.
  • Water And Moisture Proof, Does Not Decay.
  • High Tensile Strength and Elongation Properties.

Application:

Safety from electrical shock is required for workmen whether they are involved in electricity generation, transmission, distribution or its use. These mats are highly recommended for total safety of workmen from electrical shock when working in or around environment like:

  • High Voltage Panels
  • Sub-station
  • Power Transformer Rooms
  • LT & HT Labs
  • Near Bus bars
  • Near Control Panels etc.

High Voltage Mat

Request Callback

₹ 100 / Meter Get Latest Price

Product Brochure
Thickness2 mm
Voltage3.3 KV
MaterialPVC
Size1 Meter X 2 Meter
ColorBlue / Black
High Electrical Insulation ResistanceUp to 33 KV
Usage/ApplicationFor Electric Panel Room
Country of OriginMade in India

Minimum order quantity: 2 Meter

Item Code: IS-15652-2006

Voltage Ratings:


  • Class Thickness Grade KV Proof voltage B/Down voltage
  • A 2.0 mm 3.3 10KV/3 minutes 30 KV
  • B 2.5 mm 11 22KV/3 minutes 45 KV
  • C 3.0 mm 33 36KV/3 minutes 65 KV

Construction:

Made from Highly Electrical resistant Elastomers, free from any insertions (includes rubbers, latex and Elastomeric compound that may be natural or synthetic or a mixture or a combination of both)

Surface: Upper surface of the mat is having small anti-skid aberration marks (rough surface, without edges) to avoid slippery effects and lower surface is plain.

Dimensions: Sizes are 1mtr x 2mtr or long length and thickness as per classification & designation

Working Temp: -10 to 55°C

Typical Features:

  • Confirming IS: 15652/2006 (Latest), ISI marked.
  • High Die Electric Strength Up to 65 KV.
  • Insulation Resistance Up to 1494000 Mega Ohm.
  • Fire Retardant.
  • Good Mechanical Properties to with Stand Load and Movement of Breaker Trolleys and Associated Electrical Equipment including heavy foot traffic.
  • No Adverse Effect of Acids, Alkalis and Transformer Oil.
  • Manufactured Without Any Metallic Derivatives
  • Suitable For Both A.C & D.C Electrical Installations
  • Easy To Install, Can Be Pasted.
  • Water And Moisture Proof, Does Not Decay.
  • High Tensile Strength and Elongation Properties.

Application:

Safety from electrical shock is required for workmen whether they are involved in electricity generation, transmission, distribution or its use. These mats are highly recommended for total safety of workmen from electrical shock when working in or around environment like:

  • High Voltage Panels
  • Sub-station
  • Power Transformer Rooms
  • LT & HT Labs
  • Near Bus bars
  • Near Control Panels etc.

Insulation Rubber Mat

Request Callback

₹ 100 / Meter Get Latest Price

Product Brochure
Thickness2.5 mm
Voltage11 KV
Size1 Meter X 10 Meter
ColorBlue, Black, Red, Green, Grey
Usage/ApplicationFor Panel Room
Country of OriginMade in India
MaterialPVC

Minimum order quantity: 2 Meter

Item Code: IS-15652-2006

Voltage Ratings:


  • Class Thickness Grade KV Proof voltage B/Down voltage
  • A 2.0 mm 3.3 10KV/3 minutes 30 KV
  • B 2.5 mm 11 22KV/3 minutes 45 KV
  • C 3.0 mm 33 36KV/3 minutes 65 KV

Construction:

Made from Highly Electrical resistant Elastomers, free from any insertions (includes rubbers, latex and Elastomeric compound that may be natural or synthetic or a mixture or a combination of both)

Surface: Upper surface of the mat is having small anti-skid aberration marks (rough surface, without edges) to avoid slippery effects and lower surface is plain.

Dimensions: Sizes are 1mtr x 2mtr or long length and thickness as per classification & designation

Working Temp: -10 to 55°C

Typical Features:

  • Confirming IS: 15652/2006 (Latest), ISI marked.
  • High Die Electric Strength Up to 65 KV.
  • Insulation Resistance Up to 1494000 Mega Ohm.
  • Fire Retardant.
  • Good Mechanical Properties to with Stand Load and Movement of Breaker Trolleys and Associated Electrical Equipment including heavy foot traffic.
  • No Adverse Effect of Acids, Alkalis and Transformer Oil.
  • Manufactured Without Any Metallic Derivatives
  • Suitable For Both A.C & D.C Electrical Installations
  • Easy To Install, Can Be Pasted.
  • Water And Moisture Proof, Does Not Decay.
  • High Tensile Strength and Elongation Properties.

Application:

Safety from electrical shock is required for workmen whether they are involved in electricity generation, transmission, distribution or its use. These mats are highly recommended for total safety of workmen from electrical shock when working in or around environment like:

  • High Voltage Panels
  • Sub-station
  • Power Transformer Rooms
  • LT & HT Labs
  • Near Bus bars
  • Near Control Panels etc.

PVC SHOCKPROOF MAT

Request Callback

₹ 400 / Meter Get Latest Price

Product Brochure
Mat Size1 x 10
TypeMat
MaterialPVC
PatternCoin
Thickness2 mm
Country of OriginMade in India

Minimum order quantity: 1 Meter

Item Code: IS-15652-2006

Voltage Ratings:


  • Class Thickness Grade KV Proof voltage B/Down voltage
  • A 2.0 mm 3.3 10KV/3 minutes 30 KV
  • B 2.5 mm 11 22KV/3 minutes 45 KV
  • C 3.0 mm 33 36KV/3 minutes 65 KV

Construction:

Made from Highly Electrical resistant Elastomers, free from any insertions (includes rubbers, latex and Elastomeric compound that may be natural or synthetic or a mixture or a combination of both)

Surface: Upper surface of the mat is having small anti-skid aberration marks (rough surface, without edges) to avoid slippery effects and lower surface is plain.

Dimensions: Sizes are 1mtr x 2mtr or long length and thickness as per classification & designation

Working Temp: -10 to 55°C

Typical Features:

  • Confirming IS: 15652/2006 (Latest), ISI marked.
  • High Die Electric Strength Up to 65 KV.
  • Insulation Resistance Up to 1494000 Mega Ohm.
  • Fire Retardant.
  • Good Mechanical Properties to with Stand Load and Movement of Breaker Trolleys and Associated Electrical Equipment including heavy foot traffic.
  • No Adverse Effect of Acids, Alkalis and Transformer Oil.
  • Manufactured Without Any Metallic Derivatives
  • Suitable For Both A.C & D.C Electrical Installations
  • Easy To Install, Can Be Pasted.
  • Water And Moisture Proof, Does Not Decay.
  • High Tensile Strength and Elongation Properties.

Application:

Safety from electrical shock is required for workmen whether they are involved in electricity generation, transmission, distribution or its use. These mats are highly recommended for total safety of workmen from electrical shock when working in or around environment like:

  • High Voltage Panels
  • Sub-station
  • Power Transformer Rooms
  • LT & HT Labs
  • Near Bus bars
  • Near Control Panels etc.

Rubber Mats Is 5424

Request Callback

₹ 100 / Piece Get Latest Price

Product Brochure
Thickness4 mm
Size9x12 ft
TypeElectrical Rubber Mats
QualityNon Breakable
Usage/ApplicationIndustrial
ShapeRound
ColorBlack
Packaging TypeRoll
StyleMini

Minimum order quantity: 1 Piece

Item Code: IS-15652-2006

Voltage Ratings:


  • Class Thickness Grade KV Proof voltage B/Down voltage
  • A 2.0 mm 3.3 10KV/3 minutes 30 KV
  • B 2.5 mm 11 22KV/3 minutes 45 KV
  • C 3.0 mm 33 36KV/3 minutes 65 KV

Construction:

Made from Highly Electrical resistant Elastomers, free from any insertions (includes rubbers, latex and Elastomeric compound that may be natural or synthetic or a mixture or a combination of both)

Surface: Upper surface of the mat is having small anti-skid aberration marks (rough surface, without edges) to avoid slippery effects and lower surface is plain.

Dimensions: Sizes are 1mtr x 2mtr or long length and thickness as per classification & designation

Working Temp: -10 to 55°C

Typical Features:

  • Confirming IS: 15652/2006 (Latest), ISI marked.
  • High Die Electric Strength Up to 65 KV.
  • Insulation Resistance Up to 1494000 Mega Ohm.
  • Fire Retardant.
  • Good Mechanical Properties to with Stand Load and Movement of Breaker Trolleys and Associated Electrical Equipment including heavy foot traffic.
  • No Adverse Effect of Acids, Alkalis and Transformer Oil.
  • Manufactured Without Any Metallic Derivatives
  • Suitable For Both A.C & D.C Electrical Installations
  • Easy To Install, Can Be Pasted.
  • Water And Moisture Proof, Does Not Decay.
  • High Tensile Strength and Elongation Properties.

Application:

Safety from electrical shock is required for workmen whether they are involved in electricity generation, transmission, distribution or its use. These mats are highly recommended for total safety of workmen from electrical shock when working in or around environment like:

  • High Voltage Panels
  • Sub-station
  • Power Transformer Rooms
  • LT & HT Labs
  • Near Bus bars
  • Near Control Panels etc.

Rubber Checkered Electrical Mat Is 5424 1969

Request Callback

₹ 100 / Meter Get Latest Price

Product Brochure
Thickness6mm
Usage/ApplicationElectrical Insulation
ColorBlack
PatternCheckered
MaterialRubber
Country of OriginMade in India

Minimum order quantity: 1 Meter

Item Code: IS-15652-2006

Voltage Ratings:


  • Class Thickness Grade KV Proof voltage B/Down voltage
  • A 2.0 mm 3.3 10KV/3 minutes 30 KV
  • B 2.5 mm 11 22KV/3 minutes 45 KV
  • C 3.0 mm 33 36KV/3 minutes 65 KV

Construction:

Made from Highly Electrical resistant Elastomers, free from any insertions (includes rubbers, latex and Elastomeric compound that may be natural or synthetic or a mixture or a combination of both)

Surface: Upper surface of the mat is having small anti-skid aberration marks (rough surface, without edges) to avoid slippery effects and lower surface is plain.

Dimensions: Sizes are 1mtr x 2mtr or long length and thickness as per classification & designation

Working Temp: -10 to 55°C

Typical Features:

  • Confirming IS: 15652/2006 (Latest), ISI marked.
  • High Die Electric Strength Up to 65 KV.
  • Insulation Resistance Up to 1494000 Mega Ohm.
  • Fire Retardant.
  • Good Mechanical Properties to with Stand Load and Movement of Breaker Trolleys and Associated Electrical Equipment including heavy foot traffic.
  • No Adverse Effect of Acids, Alkalis and Transformer Oil.
  • Manufactured Without Any Metallic Derivatives
  • Suitable For Both A.C & D.C Electrical Installations
  • Easy To Install, Can Be Pasted.
  • Water And Moisture Proof, Does Not Decay.
  • High Tensile Strength and Elongation Properties.

Application:

Safety from electrical shock is required for workmen whether they are involved in electricity generation, transmission, distribution or its use. These mats are highly recommended for total safety of workmen from electrical shock when working in or around environment like:

  • High Voltage Panels
  • Sub-station
  • Power Transformer Rooms
  • LT & HT Labs
  • Near Bus bars
  • Near Control Panels etc.

Electrical Insulating Mat To Is 15652 2006

Request Callback

₹ 100 / Meter Get Latest Price

Product Brochure
Thickness2 mm
Voltage3.3 KV
MaterialPVC
Size1 Meter X 10 Meter
Usage/ApplicationFloor
Country of OriginMade in India

Minimum order quantity: 1 Meter

Item Code: IS-15652-2006

Voltage Ratings:


  • Class Thickness Grade KV Proof voltage B/Down voltage
  • A 2.0 mm 3.3 10KV/3 minutes 30 KV
  • B 2.5 mm 11 22KV/3 minutes 45 KV
  • C 3.0 mm 33 36KV/3 minutes 65 KV

Construction:

Made from Highly Electrical resistant Elastomers, free from any insertions (includes rubbers, latex and Elastomeric compound that may be natural or synthetic or a mixture or a combination of both)

Surface: Upper surface of the mat is having small anti-skid aberration marks (rough surface, without edges) to avoid slippery effects and lower surface is plain.

Dimensions: Sizes are 1mtr x 2mtr or long length and thickness as per classification & designation

Working Temp: -10 to 55°C

Typical Features:

  • Confirming IS: 15652/2006 (Latest), ISI marked.
  • High Die Electric Strength Up to 65 KV.
  • Insulation Resistance Up to 1494000 Mega Ohm.
  • Fire Retardant.
  • Good Mechanical Properties to with Stand Load and Movement of Breaker Trolleys and Associated Electrical Equipment including heavy foot traffic.
  • No Adverse Effect of Acids, Alkalis and Transformer Oil.
  • Manufactured Without Any Metallic Derivatives
  • Suitable For Both A.C & D.C Electrical Installations
  • Easy To Install, Can Be Pasted.
  • Water And Moisture Proof, Does Not Decay.
  • High Tensile Strength and Elongation Properties.

Application:

Safety from electrical shock is required for workmen whether they are involved in electricity generation, transmission, distribution or its use. These mats are highly recommended for total safety of workmen from electrical shock when working in or around environment like:

  • High Voltage Panels
  • Sub-station
  • Power Transformer Rooms
  • LT & HT Labs
  • Near Bus bars
  • Near Control Panels etc.

Insulating Mat Is 15652 2006

Request Callback

₹ 100 / Meter Get Latest Price

Product Brochure
Thickness2.5 mm
Voltage11 KV
MaterialPVC
Size1 X 100 Meter
Country of OriginMade in India

Minimum order quantity: 1 Meter

Item Code: IS-15652-2006

Voltage Ratings:


  • Class Thickness Grade KV Proof voltage B/Down voltage
  • A 2.0 mm 3.3 10KV/3 minutes 30 KV
  • B 2.5 mm 11 22KV/3 minutes 45 KV
  • C 3.0 mm 33 36KV/3 minutes 65 KV

Construction:

Made from Highly Electrical resistant Elastomers, free from any insertions (includes rubbers, latex and Elastomeric compound that may be natural or synthetic or a mixture or a combination of both)

Surface: Upper surface of the mat is having small anti-skid aberration marks (rough surface, without edges) to avoid slippery effects and lower surface is plain.

Dimensions: Sizes are 1mtr x 2mtr or long length and thickness as per classification & designation

Working Temp: -10 to 55°C

Typical Features:

  • Confirming IS: 15652/2006 (Latest), ISI marked.
  • High Die Electric Strength Up to 65 KV.
  • Insulation Resistance Up to 1494000 Mega Ohm.
  • Fire Retardant.
  • Good Mechanical Properties to with Stand Load and Movement of Breaker Trolleys and Associated Electrical Equipment including heavy foot traffic.
  • No Adverse Effect of Acids, Alkalis and Transformer Oil.
  • Manufactured Without Any Metallic Derivatives
  • Suitable For Both A.C & D.C Electrical Installations
  • Easy To Install, Can Be Pasted.
  • Water And Moisture Proof, Does Not Decay.
  • High Tensile Strength and Elongation Properties.

Application:

Safety from electrical shock is required for workmen whether they are involved in electricity generation, transmission, distribution or its use. These mats are highly recommended for total safety of workmen from electrical shock when working in or around environment like:

  • High Voltage Panels
  • Sub-station
  • Power Transformer Rooms
  • LT & HT Labs
  • Near Bus bars
  • Near Control Panels etc.

Rubber Checkered Electrical Mat

Request Callback

₹ 100 / Meter Get Latest Price

Product Brochure
Thickness5mm
ColorBlack
PatternCheckered
MaterialRUBBER
Country of OriginMade in India

Minimum order quantity: 2 Meter

Item Code: IS-15652-2006

Voltage Ratings:


  • Class Thickness Grade KV Proof voltage B/Down voltage
  • A 2.0 mm 3.3 10KV/3 minutes 30 KV
  • B 2.5 mm 11 22KV/3 minutes 45 KV
  • C 3.0 mm 33 36KV/3 minutes 65 KV

Construction:

Made from Highly Electrical resistant Elastomers, free from any insertions (includes rubbers, latex and Elastomeric compound that may be natural or synthetic or a mixture or a combination of both)

Surface: Upper surface of the mat is having small anti-skid aberration marks (rough surface, without edges) to avoid slippery effects and lower surface is plain.

Dimensions: Sizes are 1mtr x 2mtr or long length and thickness as per classification & designation

Working Temp: -10 to 55°C

Typical Features:

  • Confirming IS: 15652/2006 (Latest), ISI marked.
  • High Die Electric Strength Up to 65 KV.
  • Insulation Resistance Up to 1494000 Mega Ohm.
  • Fire Retardant.
  • Good Mechanical Properties to with Stand Load and Movement of Breaker Trolleys and Associated Electrical Equipment including heavy foot traffic.
  • No Adverse Effect of Acids, Alkalis and Transformer Oil.
  • Manufactured Without Any Metallic Derivatives
  • Suitable For Both A.C & D.C Electrical Installations
  • Easy To Install, Can Be Pasted.
  • Water And Moisture Proof, Does Not Decay.
  • High Tensile Strength and Elongation Properties.

Application:

Safety from electrical shock is required for workmen whether they are involved in electricity generation, transmission, distribution or its use. These mats are highly recommended for total safety of workmen from electrical shock when working in or around environment like:

  • High Voltage Panels
  • Sub-station
  • Power Transformer Rooms
  • LT & HT Labs
  • Near Bus bars
  • Near Control Panels etc.

Electrical Insulating Mats Is 15652

Request Callback

₹ 100 / Meter Get Latest Price

Product Brochure
Thickness3 mm
Voltage33 KV
Size1 METER WIDE
Usage/ApplicationELECTRICAL

Minimum order quantity: 1 Meter

Item Code: IS-15652-2006

Voltage Ratings:


  • Class Thickness Grade KV Proof voltage B/Down voltage
  • A 2.0 mm 3.3 10KV/3 minutes 30 KV
  • B 2.5 mm 11 22KV/3 minutes 45 KV
  • C 3.0 mm 33 36KV/3 minutes 65 KV

Construction:

Made from Highly Electrical resistant Elastomers, free from any insertions (includes rubbers, latex and Elastomeric compound that may be natural or synthetic or a mixture or a combination of both)

Surface: Upper surface of the mat is having small anti-skid aberration marks (rough surface, without edges) to avoid slippery effects and lower surface is plain.

Dimensions: Sizes are 1mtr x 2mtr or long length and thickness as per classification & designation

Working Temp: -10 to 55°C

Typical Features:

  • Confirming IS: 15652/2006 (Latest), ISI marked.
  • High Die Electric Strength Up to 65 KV.
  • Insulation Resistance Up to 1494000 Mega Ohm.
  • Fire Retardant.
  • Good Mechanical Properties to with Stand Load and Movement of Breaker Trolleys and Associated Electrical Equipment including heavy foot traffic.
  • No Adverse Effect of Acids, Alkalis and Transformer Oil.
  • Manufactured Without Any Metallic Derivatives
  • Suitable For Both A.C & D.C Electrical Installations
  • Easy To Install, Can Be Pasted.
  • Water And Moisture Proof, Does Not Decay.
  • High Tensile Strength and Elongation Properties.

Application:

Safety from electrical shock is required for workmen whether they are involved in electricity generation, transmission, distribution or its use. These mats are highly recommended for total safety of workmen from electrical shock when working in or around environment like:

  • High Voltage Panels
  • Sub-station
  • Power Transformer Rooms
  • LT & HT Labs
  • Near Bus bars
  • Near Control Panels etc.

Electrical Rubber Mats Is 5424

Request Callback

₹ 100 / Meter Get Latest Price

Product Brochure
Thickness5mm
ColorBlack
PatternCheckered
MaterialRUBBER
Country of OriginMade in India

Minimum order quantity: 1 Meter

Item Code: IS-15652-2006

Voltage Ratings:


  • Class Thickness Grade KV Proof voltage B/Down voltage
  • A 2.0 mm 3.3 10KV/3 minutes 30 KV
  • B 2.5 mm 11 22KV/3 minutes 45 KV
  • C 3.0 mm 33 36KV/3 minutes 65 KV

Construction:

Made from Highly Electrical resistant Elastomers, free from any insertions (includes rubbers, latex and Elastomeric compound that may be natural or synthetic or a mixture or a combination of both)

Surface: Upper surface of the mat is having small anti-skid aberration marks (rough surface, without edges) to avoid slippery effects and lower surface is plain.

Dimensions: Sizes are 1mtr x 2mtr or long length and thickness as per classification & designation

Working Temp: -10 to 55°C

Typical Features:

  • Confirming IS: 15652/2006 (Latest), ISI marked.
  • High Die Electric Strength Up to 65 KV.
  • Insulation Resistance Up to 1494000 Mega Ohm.
  • Fire Retardant.
  • Good Mechanical Properties to with Stand Load and Movement of Breaker Trolleys and Associated Electrical Equipment including heavy foot traffic.
  • No Adverse Effect of Acids, Alkalis and Transformer Oil.
  • Manufactured Without Any Metallic Derivatives
  • Suitable For Both A.C & D.C Electrical Installations
  • Easy To Install, Can Be Pasted.
  • Water And Moisture Proof, Does Not Decay.
  • High Tensile Strength and Elongation Properties.

Application:

Safety from electrical shock is required for workmen whether they are involved in electricity generation, transmission, distribution or its use. These mats are highly recommended for total safety of workmen from electrical shock when working in or around environment like:

  • High Voltage Panels
  • Sub-station
  • Power Transformer Rooms
  • LT & HT Labs
  • Near Bus bars
  • Near Control Panels etc.

Rubber Mat Is 15652 2006

Request Callback

₹ 100 / Meter Get Latest Price

Product Brochure
Thickness2mm
ColorBlue
PatternCheckered
MaterialPVC
Country of OriginMade in India

Minimum order quantity: 1 Meter

Item Code: IS-15652-2006

Voltage Ratings:


  • Class Thickness Grade KV Proof voltage B/Down voltage
  • A 2.0 mm 3.3 10KV/3 minutes 30 KV
  • B 2.5 mm 11 22KV/3 minutes 45 KV
  • C 3.0 mm 33 36KV/3 minutes 65 KV

Construction:

Made from Highly Electrical resistant Elastomers, free from any insertions (includes rubbers, latex and Elastomeric compound that may be natural or synthetic or a mixture or a combination of both)

Surface: Upper surface of the mat is having small anti-skid aberration marks (rough surface, without edges) to avoid slippery effects and lower surface is plain.

Dimensions: Sizes are 1mtr x 2mtr or long length and thickness as per classification & designation

Working Temp: -10 to 55°C

Typical Features:

  • Confirming IS: 15652/2006 (Latest), ISI marked.
  • High Die Electric Strength Up to 65 KV.
  • Insulation Resistance Up to 1494000 Mega Ohm.
  • Fire Retardant.
  • Good Mechanical Properties to with Stand Load and Movement of Breaker Trolleys and Associated Electrical Equipment including heavy foot traffic.
  • No Adverse Effect of Acids, Alkalis and Transformer Oil.
  • Manufactured Without Any Metallic Derivatives
  • Suitable For Both A.C & D.C Electrical Installations
  • Easy To Install, Can Be Pasted.
  • Water And Moisture Proof, Does Not Decay.
  • High Tensile Strength and Elongation Properties.

Application:

Safety from electrical shock is required for workmen whether they are involved in electricity generation, transmission, distribution or its use. These mats are highly recommended for total safety of workmen from electrical shock when working in or around environment like:

  • High Voltage Panels
  • Sub-station
  • Power Transformer Rooms
  • LT & HT Labs
  • Near Bus bars
  • Near Control Panels etc.

Pvc Insulation Mat

Request Callback

₹ 100 / Meter Get Latest Price

Product Brochure
Thickness2.5 mm
Voltage11 KV
Size10 METER
ColorANY ONE
Usage/ApplicationPANEL ROOM
Country of OriginMade in India

Minimum order quantity: 2 Meter

Item Code: IS-15652-2006

Voltage Ratings:


  • Class Thickness Grade KV Proof voltage B/Down voltage
  • A 2.0 mm 3.3 10KV/3 minutes 30 KV
  • B 2.5 mm 11 22KV/3 minutes 45 KV
  • C 3.0 mm 33 36KV/3 minutes 65 KV

Construction:

Made from Highly Electrical resistant Elastomers, free from any insertions (includes rubbers, latex and Elastomeric compound that may be natural or synthetic or a mixture or a combination of both)

Surface: Upper surface of the mat is having small anti-skid aberration marks (rough surface, without edges) to avoid slippery effects and lower surface is plain.

Dimensions: Sizes are 1mtr x 2mtr or long length and thickness as per classification & designation

Working Temp: -10 to 55°C

Typical Features:

  • Confirming IS: 15652/2006 (Latest), ISI marked.
  • High Die Electric Strength Up to 65 KV.
  • Insulation Resistance Up to 1494000 Mega Ohm.
  • Fire Retardant.
  • Good Mechanical Properties to with Stand Load and Movement of Breaker Trolleys and Associated Electrical Equipment including heavy foot traffic.
  • No Adverse Effect of Acids, Alkalis and Transformer Oil.
  • Manufactured Without Any Metallic Derivatives
  • Suitable For Both A.C & D.C Electrical Installations
  • Easy To Install, Can Be Pasted.
  • Water And Moisture Proof, Does Not Decay.
  • High Tensile Strength and Elongation Properties.

Application:

Safety from electrical shock is required for workmen whether they are involved in electricity generation, transmission, distribution or its use. These mats are highly recommended for total safety of workmen from electrical shock when working in or around environment like:

  • High Voltage Panels
  • Sub-station
  • Power Transformer Rooms
  • LT & HT Labs
  • Near Bus bars
  • Near Control Panels etc.

Pvc Electrical Insulation Mat

Request Callback

₹ 100 / Meter Get Latest Price

Product Brochure
Thickness2 mm
Voltage3.3 KV
MaterialPVC
Size10 METER
Usage/ApplicationELECTRICAL FLOORING

Minimum order quantity: 2 Meter

Item Code: IS-15652-2006

Voltage Ratings:


  • Class Thickness Grade KV Proof voltage B/Down voltage
  • A 2.0 mm 3.3 10KV/3 minutes 30 KV
  • B 2.5 mm 11 22KV/3 minutes 45 KV
  • C 3.0 mm 33 36KV/3 minutes 65 KV

Construction:

Made from Highly Electrical resistant Elastomers, free from any insertions (includes rubbers, latex and Elastomeric compound that may be natural or synthetic or a mixture or a combination of both)

Surface: Upper surface of the mat is having small anti-skid aberration marks (rough surface, without edges) to avoid slippery effects and lower surface is plain.

Dimensions: Sizes are 1mtr x 2mtr or long length and thickness as per classification & designation

Working Temp: -10 to 55°C

Typical Features:

  • Confirming IS: 15652/2006 (Latest), ISI marked.
  • High Die Electric Strength Up to 65 KV.
  • Insulation Resistance Up to 1494000 Mega Ohm.
  • Fire Retardant.
  • Good Mechanical Properties to with Stand Load and Movement of Breaker Trolleys and Associated Electrical Equipment including heavy foot traffic.
  • No Adverse Effect of Acids, Alkalis and Transformer Oil.
  • Manufactured Without Any Metallic Derivatives
  • Suitable For Both A.C & D.C Electrical Installations
  • Easy To Install, Can Be Pasted.
  • Water And Moisture Proof, Does Not Decay.
  • High Tensile Strength and Elongation Properties.

Application:

Safety from electrical shock is required for workmen whether they are involved in electricity generation, transmission, distribution or its use. These mats are highly recommended for total safety of workmen from electrical shock when working in or around environment like:

  • High Voltage Panels
  • Sub-station
  • Power Transformer Rooms
  • LT & HT Labs
  • Near Bus bars
  • Near Control Panels etc.

Electrical Floor Mats

Request Callback

₹ 800 / Piece Get Latest Price

Product Brochure
Mat Size24 x 36 inch
Thickness2 mm
Voltage11 KV
PatternCOIN
Size1 Meter X 10 Meter
Country of OriginMade in India
MaterialRUBBER / PVC

Minimum order quantity: 2 Piece

Item Code: IS-15652-2006

Voltage Ratings:


  • Class Thickness Grade KV Proof voltage B/Down voltage
  • A 2.0 mm 3.3 10KV/3 minutes 30 KV
  • B 2.5 mm 11 22KV/3 minutes 45 KV
  • C 3.0 mm 33 36KV/3 minutes 65 KV

Construction:

Made from Highly Electrical resistant Elastomers, free from any insertions (includes rubbers, latex and Elastomeric compound that may be natural or synthetic or a mixture or a combination of both)

Surface: Upper surface of the mat is having small anti-skid aberration marks (rough surface, without edges) to avoid slippery effects and lower surface is plain.

Dimensions: Sizes are 1mtr x 2mtr or long length and thickness as per classification & designation

Working Temp: -10 to 55°C

Typical Features:

  • Confirming IS: 15652/2006 (Latest), ISI marked.
  • High Die Electric Strength Up to 65 KV.
  • Insulation Resistance Up to 1494000 Mega Ohm.
  • Fire Retardant.
  • Good Mechanical Properties to with Stand Load and Movement of Breaker Trolleys and Associated Electrical Equipment including heavy foot traffic.
  • No Adverse Effect of Acids, Alkalis and Transformer Oil.
  • Manufactured Without Any Metallic Derivatives
  • Suitable For Both A.C & D.C Electrical Installations
  • Easy To Install, Can Be Pasted.
  • Water And Moisture Proof, Does Not Decay.
  • High Tensile Strength and Elongation Properties.

Application:

Safety from electrical shock is required for workmen whether they are involved in electricity generation, transmission, distribution or its use. These mats are highly recommended for total safety of workmen from electrical shock when working in or around environment like:

  • High Voltage Panels
  • Sub-station
  • Power Transformer Rooms
  • LT & HT Labs
  • Near Bus bars
  • Near Control Panels etc.

ASTM D Electrical Insulation Rubber Mat

Request Callback

₹ 1300 / Meter Get Latest Price

Product Brochure
Thickness3.2
ColorBlack
PatternPlain
MaterialRubber
Country of OriginMade in India

Minimum order quantity: 1 Meter

We deliver rubber insulating mattings that are designed according to the ASTM-D-178 Standard. This standard is set by the American Society for Testing and Materials. The ASTM-D-178 Standard endorses a thickness of 3.2mm to 12.7mm for these particular mattings. It depends upon the smooth lower surface with the usage/working voltage resistance & antiskid textured surface on the top. Such safety rubber mattings (Type-1 Grade) are moisture, water & leakage proof that guarantee a long functional (work) life. A Type-2 Grade Insulating Mat contains certain additional properties such as Flame & Ozone resistance.

 

 

Product Code

Class

Recommended Thickness

Max Use/Working Voltage

AC Proof Voltage

Di-electric strength (Withstand Voltage)

Approx. Weight Per Sqr Mtr.

ASTM 001

0

3.2 mm

1.0 KV

5.0 KV

6.0 KV

5.0 Kgs

ASTM 002

1

4.8 mm

7.5 KV

10.0 KV

20.0 KV

7.5 Kgs

ASTM 003

2

6.4 mm

17.0 KV

20.0 KV

30.0 KV

10.0 Kgs

ASTM 004

3

9.5 mm

26.5 KV

30.0 KV

40.0 KV

15.0 Kgs

ASTM 005

4

12.7 mm

36.0 KV

40.0 KV

50.0 KV

20.0 Kgs

ASTM CD (Custom)

-

Upto 25.0 mm

Upto 36.0 KV

Upto 40.0 KV

Upto 50.0 KV

-

 

Sl No.

Features

Values

1

Standard Size & Design

1) 1.0 Mtr. Wide x 10.0 Mtr. Long. in Texture Design.

2) 1.2 Mtr. Wide x 10.0 Mtr. Long. in Texture Design

2

Custom Size & Design

Max. width upto 2400mm, length upto 20M and thickness upto 25mm available in Texture Design only

3

Standard Colour

Black & Blue without Metallic Derivatives. (Other colours available on request subject to availability.)

4

Manufacturing Tolerance

±10% on thickness, ±5% on length, ±2% on width

5

Type

Unless specified, insulating matting shall be supplied as per Type I grade. Also available on request, Type II grade (A-Ozone Resistance, B-Flame Resistance, C-Oil Resistance) with combination of all three or individual properties.

 

Standard Size & Design

1.0 Mtr Wide x 10.0 Mtr Long in Textured Design

Standard Colour

Black & Blue without Metallic Derivatives (Other colours available on request subject to availability)

ASTM D Insulation Rubber Mat

Request Callback

₹ 1000 / Meter Get Latest Price

Product Brochure
Thickness10 mm
Voltage11 KV
ColorBlack
Usage/ApplicationElectrical Room
MaterialRubber
Size1 Meter X 10 Meter
Country of OriginMade in India

Minimum order quantity: 1 Meter

We deliver rubber insulating mattings that are designed according to the ASTM-D-178 Standard. This standard is set by the American Society for Testing and Materials. The ASTM-D-178 Standard endorses a thickness of 3.2mm to 12.7mm for these particular mattings. It depends upon the smooth lower surface with the usage/working voltage resistance & antiskid textured surface on the top. Such safety rubber mattings (Type-1 Grade) are moisture, water & leakage proof that guarantee a long functional (work) life. A Type-2 Grade Insulating Mat contains certain additional properties such as Flame & Ozone resistance.

 

 

Product Code

Class

Recommended Thickness

Max Use/Working Voltage

AC Proof Voltage

Di-electric strength (Withstand Voltage)

Approx. Weight Per Sqr Mtr.

ASTM 001

0

3.2 mm

1.0 KV

5.0 KV

6.0 KV

5.0 Kgs

ASTM 002

1

4.8 mm

7.5 KV

10.0 KV

20.0 KV

7.5 Kgs

ASTM 003

2

6.4 mm

17.0 KV

20.0 KV

30.0 KV

10.0 Kgs

ASTM 004

3

9.5 mm

26.5 KV

30.0 KV

40.0 KV

15.0 Kgs

ASTM 005

4

12.7 mm

36.0 KV

40.0 KV

50.0 KV

20.0 Kgs

ASTM CD (Custom)

-

Upto 25.0 mm

Upto 36.0 KV

Upto 40.0 KV

Upto 50.0 KV

-

 

Sl No.

Features

Values

1

Standard Size & Design

1) 1.0 Mtr. Wide x 10.0 Mtr. Long. in Texture Design.

2) 1.2 Mtr. Wide x 10.0 Mtr. Long. in Texture Design

2

Custom Size & Design

Max. width upto 2400mm, length upto 20M and thickness upto 25mm available in Texture Design only

3

Standard Colour

Black & Blue without Metallic Derivatives. (Other colours available on request subject to availability.)

4

Manufacturing Tolerance

±10% on thickness, ±5% on length, ±2% on width

5

Type

Unless specified, insulating matting shall be supplied as per Type I grade. Also available on request, Type II grade (A-Ozone Resistance, B-Flame Resistance, C-Oil Resistance) with combination of all three or individual properties.

 

Standard Size & Design

1.0 Mtr Wide x 10.0 Mtr Long in Textured Design

Standard Colour

Black & Blue without Metallic Derivatives (Other colours available on request subject to availability)

Pvc Rubber Mats

Request Callback

₹ 700 / Piece Get Latest Price

Product Brochure
Size2x3 ft
TypeElectrical Rubber Mats
QualityNon Breakable
Thickness2 mm
Usage/ApplicationIndustrial
ColorGrey
Packaging TypeRoll
StyleMini

Minimum order quantity: 1 Piece

Insulating Matting (Di-Electric Carpets) made of Rubber Compound suitable for providing the Electrical safety to the workmen working around the possible areas of Electrical shock and act as a safeguard equipment from electrical shock due to leakage of current, shot circuit or any other. The special high quality Rubber Compound ensures the complete shock protection against electrical shocks due to electrical earth faults.

Our Mats are fully compliant With IEC 61111 (International Electro Technical Commission) and are regularly tested by third like TUV, Lloyds and many others. The mats offered by us are ROHS and PAH Compliant.

Features And Advantages
  • Fully tested to specification IEC 61111.
  • Provides safety for operators against electrical shock.
  • High Electrical Resistance Up to 50 KV/50000 volts.
  • Suitable for both AC and DC Applications.
  • Health and safety regulation Halogen Free flame retardant material.
  • Highly Flexible mats with self-gripping design on floor.
  • Anti-Fatigue type. Comfortable while standing for long period.
  • Anti-Slip Finish. Tested to slip resist test.
  • Resistant to acid, oil and Low temperature test.
  • Ozone, UV and weather resistant.
  • Permanent Marking-Durable and un-erasable done while curing of mats.
  • Fully Traceable supply.
  • Low Maintainance.
  • No Recycled Rubber.
ClassStandard ThicknessMax. Use VoltageProof VoltageWithstand VoltageColor Code
0 3 mm 1000 Volts 5000 Volts 10000 Volts Red
1 3 mm 7500 Volts 10000 Volts 20000 Volts White
2 3/6 mm 17000 Volts 20000 Volts 30000 Volts Yellow
3 4/6 mm 26500 Volts 30000 Volts 40000 Volts Green
4 4/6 mm 36000 Volts 40000 Volts 50000 Volts Orange

 

Dimensions
Width 0.9mtr, 1.0mtr, 1.2mtr
Length 2mtr, 5mtr, 10mtr, 20mtr, or as per requirement
Thickness As Per Specified Class
Colors Black, Blue, Grey
Surface/Design Anti-Skid Texture Finish

Note: Other colors also available on request.

Other Properties
S.No.Technical SpecificationAll Classes
1 Composition and Surface Rubber elastomer*, Anti Skid Finish. Macromolecular material which returns rapidly to its final dimension by a weak stress and release of the stress.
2 Workmanship Mats shall be free from Harmful physical irregularities.
3 Mechanical Puncture Resistance Min. 70N
4 Slip Resistance Test @ force of 70N Maximum 15mm
5 Ageing Test at 70 deg cl./168hrs. Puncture Resistance shall be min. 80% of original value.
6 Flame Retardant Test Flame shall not reach any point on a 50mm circle.
7 Thermal Test (Low Temp. Test) No Crack@100N.
No-Breakdown on specified voltage.
8 Acid Test; H2SO4 For 8hrs. Minimum Retention in Mech. Puncture Test initial value. Min. 75% Retention & No Breakdown on specified Voltage.
9 Oil Test; oil for 2hrs.
Minimum Retention in Mech. Puncture test initial value.
Min. 75% Retention & No Breakdown on specified Voltage.

IEC Electrical Insulation Mat

Request Callback

₹ 400 / Meter Get Latest Price

Product Brochure
Thickness3 mm
Voltage11 KV
MaterialRubber
Size1 Meter Wide
ColorBlack
Usage/ApplicationIndustrial
Country of OriginMade in India

Minimum order quantity: 1 Meter

Insulating Matting (Di-Electric Carpets) made of Rubber Compound suitable for providing the Electrical safety to the workmen working around the possible areas of Electrical shock and act as a safeguard equipment from electrical shock due to leakage of current, shot circuit or any other. The special high quality Rubber Compound ensures the complete shock protection against electrical shocks due to electrical earth faults.

Our Mats are fully compliant With IEC 61111 (International Electro Technical Commission) and are regularly tested by third like TUV, Lloyds and many others. The mats offered by us are ROHS and PAH Compliant.

Features And Advantages
  • Fully tested to specification IEC 61111.
  • Provides safety for operators against electrical shock.
  • High Electrical Resistance Up to 50 KV/50000 volts.
  • Suitable for both AC and DC Applications.
  • Health and safety regulation Halogen Free flame retardant material.
  • Highly Flexible mats with self-gripping design on floor.
  • Anti-Fatigue type. Comfortable while standing for long period.
  • Anti-Slip Finish. Tested to slip resist test.
  • Resistant to acid, oil and Low temperature test.
  • Ozone, UV and weather resistant.
  • Permanent Marking-Durable and un-erasable done while curing of mats.
  • Fully Traceable supply.
  • Low Maintainance.
  • No Recycled Rubber.
ClassStandard ThicknessMax. Use VoltageProof VoltageWithstand VoltageColor Code
0 3 mm 1000 Volts 5000 Volts 10000 Volts Red
1 3 mm 7500 Volts 10000 Volts 20000 Volts White
2 3/6 mm 17000 Volts 20000 Volts 30000 Volts Yellow
3 4/6 mm 26500 Volts 30000 Volts 40000 Volts Green
4 4/6 mm 36000 Volts 40000 Volts 50000 Volts Orange

 

Dimensions
Width 0.9mtr, 1.0mtr, 1.2mtr
Length 2mtr, 5mtr, 10mtr, 20mtr, or as per requirement
Thickness As Per Specified Class
Colors Black, Blue, Grey
Surface/Design Anti-Skid Texture Finish

Note: Other colors also available on request.

Other Properties
S.No.Technical SpecificationAll Classes
1 Composition and Surface Rubber elastomer*, Anti Skid Finish. Macromolecular material which returns rapidly to its final dimension by a weak stress and release of the stress.
2 Workmanship Mats shall be free from Harmful physical irregularities.
3 Mechanical Puncture Resistance Min. 70N
4 Slip Resistance Test @ force of 70N Maximum 15mm
5 Ageing Test at 70 deg cl./168hrs. Puncture Resistance shall be min. 80% of original value.
6 Flame Retardant Test Flame shall not reach any point on a 50mm circle.
7 Thermal Test (Low Temp. Test) No Crack@100N.
No-Breakdown on specified voltage.
8 Acid Test; H2SO4 For 8hrs. Minimum Retention in Mech. Puncture Test initial value. Min. 75% Retention & No Breakdown on specified Voltage.
9 Oil Test; oil for 2hrs.
Minimum Retention in Mech. Puncture test initial value.
Min. 75% Retention & No Breakdown on specified Voltage.

IEC 61111 Rubber Insulation Mats

Request Callback

₹ 500 / Meter Get Latest Price

Product Brochure
Thickness6 mm
Voltage33 KV
ColorBlack
Usage/ApplicationElectrical
MaterialRubber
Size1 Meter X 10 Meter
Country of OriginMade in India

Minimum order quantity: 1 Meter

Insulating Matting (Di-Electric Carpets) made of Rubber Compound suitable for providing the Electrical safety to the workmen working around the possible areas of Electrical shock and act as a safeguard equipment from electrical shock due to leakage of current, shot circuit or any other. The special high quality Rubber Compound ensures the complete shock protection against electrical shocks due to electrical earth faults.

Our Mats are fully compliant With IEC 61111 (International Electro Technical Commission) and are regularly tested by third like TUV, Lloyds and many others. The mats offered by us are ROHS and PAH Compliant.

Features And Advantages
  • Fully tested to specification IEC 61111.
  • Provides safety for operators against electrical shock.
  • High Electrical Resistance Up to 50 KV/50000 volts.
  • Suitable for both AC and DC Applications.
  • Health and safety regulation Halogen Free flame retardant material.
  • Highly Flexible mats with self-gripping design on floor.
  • Anti-Fatigue type. Comfortable while standing for long period.
  • Anti-Slip Finish. Tested to slip resist test.
  • Resistant to acid, oil and Low temperature test.
  • Ozone, UV and weather resistant.
  • Permanent Marking-Durable and un-erasable done while curing of mats.
  • Fully Traceable supply.
  • Low Maintainance.
  • No Recycled Rubber.
ClassStandard ThicknessMax. Use VoltageProof VoltageWithstand VoltageColor Code
0 3 mm 1000 Volts 5000 Volts 10000 Volts Red
1 3 mm 7500 Volts 10000 Volts 20000 Volts White
2 3/6 mm 17000 Volts 20000 Volts 30000 Volts Yellow
3 4/6 mm 26500 Volts 30000 Volts 40000 Volts Green
4 4/6 mm 36000 Volts 40000 Volts 50000 Volts Orange

 

Dimensions
Width 0.9mtr, 1.0mtr, 1.2mtr
Length 2mtr, 5mtr, 10mtr, 20mtr, or as per requirement
Thickness As Per Specified Class
Colors Black, Blue, Grey
Surface/Design Anti-Skid Texture Finish

Note: Other colors also available on request.

Other Properties
S.No.Technical SpecificationAll Classes
1 Composition and Surface Rubber elastomer*, Anti Skid Finish. Macromolecular material which returns rapidly to its final dimension by a weak stress and release of the stress.
2 Workmanship Mats shall be free from Harmful physical irregularities.
3 Mechanical Puncture Resistance Min. 70N
4 Slip Resistance Test @ force of 70N Maximum 15mm
5 Ageing Test at 70 deg cl./168hrs. Puncture Resistance shall be min. 80% of original value.
6 Flame Retardant Test Flame shall not reach any point on a 50mm circle.
7 Thermal Test (Low Temp. Test) No Crack@100N.
No-Breakdown on specified voltage.
8 Acid Test; H2SO4 For 8hrs. Minimum Retention in Mech. Puncture Test initial value. Min. 75% Retention & No Breakdown on specified Voltage.
9 Oil Test; oil for 2hrs.
Minimum Retention in Mech. Puncture test initial value.
Min. 75% Retention & No Breakdown on specified Voltage.

IEC Electrical Rubber Insulation Mat

Request Callback

₹ 600 / Meter Get Latest Price

Product Brochure
Thickness4mm
Usage/ApplicationElectrical Insulation
ColorBlack
PatternCheckered
BrandMITC
MaterialRubber
Country of OriginMade in India

Minimum order quantity: 10 Meter

Insulating Matting (Di-Electric Carpets) made of Rubber Compound suitable for providing the Electrical safety to the workmen working around the possible areas of Electrical shock and act as a safeguard equipment from electrical shock due to leakage of current, shot circuit or any other. The special high quality Rubber Compound ensures the complete shock protection against electrical shocks due to electrical earth faults.

Our Mats are fully compliant With IEC 61111 (International Electro Technical Commission) and are regularly tested by third like TUV, Lloyds and many others. The mats offered by us are ROHS and PAH Compliant.

Features And Advantages
  • Fully tested to specification IEC 61111.
  • Provides safety for operators against electrical shock.
  • High Electrical Resistance Up to 50 KV/50000 volts.
  • Suitable for both AC and DC Applications.
  • Health and safety regulation Halogen Free flame retardant material.
  • Highly Flexible mats with self-gripping design on floor.
  • Anti-Fatigue type. Comfortable while standing for long period.
  • Anti-Slip Finish. Tested to slip resist test.
  • Resistant to acid, oil and Low temperature test.
  • Ozone, UV and weather resistant.
  • Permanent Marking-Durable and un-erasable done while curing of mats.
  • Fully Traceable supply.
  • Low Maintainance.
  • No Recycled Rubber.
ClassStandard ThicknessMax. Use VoltageProof VoltageWithstand VoltageColor Code
0 3 mm 1000 Volts 5000 Volts 10000 Volts Red
1 3 mm 7500 Volts 10000 Volts 20000 Volts White
2 3/6 mm 17000 Volts 20000 Volts 30000 Volts Yellow
3 4/6 mm 26500 Volts 30000 Volts 40000 Volts Green
4 4/6 mm 36000 Volts 40000 Volts 50000 Volts Orange

 

Dimensions
Width 0.9mtr, 1.0mtr, 1.2mtr
Length 2mtr, 5mtr, 10mtr, 20mtr, or as per requirement
Thickness As Per Specified Class
Colors Black, Blue, Grey
Surface/Design Anti-Skid Texture Finish

Note: Other colors also available on request.

Other Properties
S.No.Technical SpecificationAll Classes
1 Composition and Surface Rubber elastomer*, Anti Skid Finish. Macromolecular material which returns rapidly to its final dimension by a weak stress and release of the stress.
2 Workmanship Mats shall be free from Harmful physical irregularities.
3 Mechanical Puncture Resistance Min. 70N
4 Slip Resistance Test @ force of 70N Maximum 15mm
5 Ageing Test at 70 deg cl./168hrs. Puncture Resistance shall be min. 80% of original value.
6 Flame Retardant Test Flame shall not reach any point on a 50mm circle.
7 Thermal Test (Low Temp. Test) No Crack@100N.
No-Breakdown on specified voltage.
8 Acid Test; H2SO4 For 8hrs. Minimum Retention in Mech. Puncture Test initial value. Min. 75% Retention & No Breakdown on specified Voltage.
9 Oil Test; oil for 2hrs.
Minimum Retention in Mech. Puncture test initial value.
Min. 75% Retention & No Breakdown on specified Voltage.

IEC 61111 Electrical Rubber Insulation Mats

Request Callback

₹ 800 / Meter Get Latest Price

Product Brochure
Thickness6 mm
Voltage11 KV
ColorBlack / Grey
Usage/ApplicationElectrical Panel Room
MaterialRubber
Size1 Meter X 10 Meter
Country of OriginMade in India

Minimum order quantity: 10 Meter

Insulating Matting (Di-Electric Carpets) made of Rubber Compound suitable for providing the Electrical safety to the workmen working around the possible areas of Electrical shock and act as a safeguard equipment from electrical shock due to leakage of current, shot circuit or any other. The special high quality Rubber Compound ensures the complete shock protection against electrical shocks due to electrical earth faults.

Our Mats are fully compliant With IEC 61111 (International Electro Technical Commission) and are regularly tested by third like TUV, Lloyds and many others. The mats offered by us are ROHS and PAH Compliant.

Features And Advantages
  • Fully tested to specification IEC 61111.
  • Provides safety for operators against electrical shock.
  • High Electrical Resistance Up to 50 KV/50000 volts.
  • Suitable for both AC and DC Applications.
  • Health and safety regulation Halogen Free flame retardant material.
  • Highly Flexible mats with self-gripping design on floor.
  • Anti-Fatigue type. Comfortable while standing for long period.
  • Anti-Slip Finish. Tested to slip resist test.
  • Resistant to acid, oil and Low temperature test.
  • Ozone, UV and weather resistant.
  • Permanent Marking-Durable and un-erasable done while curing of mats.
  • Fully Traceable supply.
  • Low Maintainance.
  • No Recycled Rubber.
ClassStandard ThicknessMax. Use VoltageProof VoltageWithstand VoltageColor Code
0 3 mm 1000 Volts 5000 Volts 10000 Volts Red
1 3 mm 7500 Volts 10000 Volts 20000 Volts White
2 3/6 mm 17000 Volts 20000 Volts 30000 Volts Yellow
3 4/6 mm 26500 Volts 30000 Volts 40000 Volts Green
4 4/6 mm 36000 Volts 40000 Volts 50000 Volts Orange

 

Dimensions
Width 0.9mtr, 1.0mtr, 1.2mtr
Length 2mtr, 5mtr, 10mtr, 20mtr, or as per requirement
Thickness As Per Specified Class
Colors Black, Blue, Grey
Surface/Design Anti-Skid Texture Finish

Note: Other colors also available on request.

Other Properties
S.No.Technical SpecificationAll Classes
1 Composition and Surface Rubber elastomer*, Anti Skid Finish. Macromolecular material which returns rapidly to its final dimension by a weak stress and release of the stress.
2 Workmanship Mats shall be free from Harmful physical irregularities.
3 Mechanical Puncture Resistance Min. 70N
4 Slip Resistance Test @ force of 70N Maximum 15mm
5 Ageing Test at 70 deg cl./168hrs. Puncture Resistance shall be min. 80% of original value.
6 Flame Retardant Test Flame shall not reach any point on a 50mm circle.
7 Thermal Test (Low Temp. Test) No Crack@100N.
No-Breakdown on specified voltage.
8 Acid Test; H2SO4 For 8hrs. Minimum Retention in Mech. Puncture Test initial value. Min. 75% Retention & No Breakdown on specified Voltage.
9 Oil Test; oil for 2hrs.
Minimum Retention in Mech. Puncture test initial value.
Min. 75% Retention & No Breakdown on specified Voltage.

IEC 61111 Electrical Insulation Mats

Request Callback

₹ 900 / Meter Get Latest Price

Product Brochure
Thickness4mm
Voltage11 KV
MaterialRubber
Size10 Meter Long
ColorGrey
Usage/ApplicationPanel Room
Country of OriginMade in India

Minimum order quantity: 1 Meter

Insulating Matting (Di-Electric Carpets) made of Rubber Compound suitable for providing the Electrical safety to the workmen working around the possible areas of Electrical shock and act as a safeguard equipment from electrical shock due to leakage of current, shot circuit or any other. The special high quality Rubber Compound ensures the complete shock protection against electrical shocks due to electrical earth faults.

Our Mats are fully compliant With IEC 61111 (International Electro Technical Commission) and are regularly tested by third like TUV, Lloyds and many others. The mats offered by us are ROHS and PAH Compliant.

Features And Advantages
  • Fully tested to specification IEC 61111.
  • Provides safety for operators against electrical shock.
  • High Electrical Resistance Up to 50 KV/50000 volts.
  • Suitable for both AC and DC Applications.
  • Health and safety regulation Halogen Free flame retardant material.
  • Highly Flexible mats with self-gripping design on floor.
  • Anti-Fatigue type. Comfortable while standing for long period.
  • Anti-Slip Finish. Tested to slip resist test.
  • Resistant to acid, oil and Low temperature test.
  • Ozone, UV and weather resistant.
  • Permanent Marking-Durable and un-erasable done while curing of mats.
  • Fully Traceable supply.
  • Low Maintainance.
  • No Recycled Rubber.
ClassStandard ThicknessMax. Use VoltageProof VoltageWithstand VoltageColor Code
0 3 mm 1000 Volts 5000 Volts 10000 Volts Red
1 3 mm 7500 Volts 10000 Volts 20000 Volts White
2 3/6 mm 17000 Volts 20000 Volts 30000 Volts Yellow
3 4/6 mm 26500 Volts 30000 Volts 40000 Volts Green
4 4/6 mm 36000 Volts 40000 Volts 50000 Volts Orange

 

Dimensions
Width 0.9mtr, 1.0mtr, 1.2mtr
Length 2mtr, 5mtr, 10mtr, 20mtr, or as per requirement
Thickness As Per Specified Class
Colors Black, Blue, Grey
Surface/Design Anti-Skid Texture Finish

Note: Other colors also available on request.

Other Properties
S.No.Technical SpecificationAll Classes
1 Composition and Surface Rubber elastomer*, Anti Skid Finish. Macromolecular material which returns rapidly to its final dimension by a weak stress and release of the stress.
2 Workmanship Mats shall be free from Harmful physical irregularities.
3 Mechanical Puncture Resistance Min. 70N
4 Slip Resistance Test @ force of 70N Maximum 15mm
5 Ageing Test at 70 deg cl./168hrs. Puncture Resistance shall be min. 80% of original value.
6 Flame Retardant Test Flame shall not reach any point on a 50mm circle.
7 Thermal Test (Low Temp. Test) No Crack@100N.
No-Breakdown on specified voltage.
8 Acid Test; H2SO4 For 8hrs. Minimum Retention in Mech. Puncture Test initial value. Min. 75% Retention & No Breakdown on specified Voltage.
9 Oil Test; oil for 2hrs.
Minimum Retention in Mech. Puncture test initial value.
Min. 75% Retention & No Breakdown on specified Voltage.

Iec 61111 Insulation Mats

Request Callback

₹ 100 / Meter Get Latest Price

Product Brochure
Thickness3 mm
Voltage11 KV
MaterialRubber
Size1 Meter X 10 Meter
ColorBlac
Usage/ApplicationElectrical Panel room
Country of OriginMade in India

Minimum order quantity: 100 Meter

Insulating Matting (Di-Electric Carpets) made of Rubber Compound suitable for providing the Electrical safety to the workmen working around the possible areas of Electrical shock and act as a safeguard equipment from electrical shock due to leakage of current, shot circuit or any other. The special high quality Rubber Compound ensures the complete shock protection against electrical shocks due to electrical earth faults.

Our Mats are fully compliant With IEC 61111 (International Electro Technical Commission) and are regularly tested by third like TUV, Lloyds and many others. The mats offered by us are ROHS and PAH Compliant.

Features And Advantages
  • Fully tested to specification IEC 61111.
  • Provides safety for operators against electrical shock.
  • High Electrical Resistance Up to 50 KV/50000 volts.
  • Suitable for both AC and DC Applications.
  • Health and safety regulation Halogen Free flame retardant material.
  • Highly Flexible mats with self-gripping design on floor.
  • Anti-Fatigue type. Comfortable while standing for long period.
  • Anti-Slip Finish. Tested to slip resist test.
  • Resistant to acid, oil and Low temperature test.
  • Ozone, UV and weather resistant.
  • Permanent Marking-Durable and un-erasable done while curing of mats.
  • Fully Traceable supply.
  • Low Maintainance.
  • No Recycled Rubber.
ClassStandard ThicknessMax. Use VoltageProof VoltageWithstand VoltageColor Code
0 3 mm 1000 Volts 5000 Volts 10000 Volts Red
1 3 mm 7500 Volts 10000 Volts 20000 Volts White
2 3/6 mm 17000 Volts 20000 Volts 30000 Volts Yellow
3 4/6 mm 26500 Volts 30000 Volts 40000 Volts Green
4 4/6 mm 36000 Volts 40000 Volts 50000 Volts Orange

 

Dimensions
Width 0.9mtr, 1.0mtr, 1.2mtr
Length 2mtr, 5mtr, 10mtr, 20mtr, or as per requirement
Thickness As Per Specified Class
Colors Black, Blue, Grey
Surface/Design Anti-Skid Texture Finish

Note: Other colors also available on request.

Other Properties
S.No.Technical SpecificationAll Classes
1 Composition and Surface Rubber elastomer*, Anti Skid Finish. Macromolecular material which returns rapidly to its final dimension by a weak stress and release of the stress.
2 Workmanship Mats shall be free from Harmful physical irregularities.
3 Mechanical Puncture Resistance Min. 70N
4 Slip Resistance Test @ force of 70N Maximum 15mm
5 Ageing Test at 70 deg cl./168hrs. Puncture Resistance shall be min. 80% of original value.
6 Flame Retardant Test Flame shall not reach any point on a 50mm circle.
7 Thermal Test (Low Temp. Test) No Crack@100N.
No-Breakdown on specified voltage.
8 Acid Test; H2SO4 For 8hrs. Minimum Retention in Mech. Puncture Test initial value. Min. 75% Retention & No Breakdown on specified Voltage.
9 Oil Test; oil for 2hrs.
Minimum Retention in Mech. Puncture test initial value.
Min. 75% Retention & No Breakdown on specified Voltage.

Electrical Insulation Mat Is 15652 2006

Request Callback

₹ 100 / Meter Get Latest Price

Product Brochure
Thickness3 mm
Voltage33 KV
IS15652 : 2006

Minimum order quantity: 1 Meter

Item Code: IS-15652-2006

Voltage Ratings:


  • Class Thickness Grade KV Proof voltage B/Down voltage
  • A 2.0 mm 3.3 10KV/3 minutes 30 KV
  • B 2.5 mm 11 22KV/3 minutes 45 KV
  • C 3.0 mm 33 36KV/3 minutes 65 KV

Construction:

Made from Highly Electrical resistant Elastomers, free from any insertions (includes rubbers, latex and Elastomeric compound that may be natural or synthetic or a mixture or a combination of both)

Surface: Upper surface of the mat is having small anti-skid aberration marks (rough surface, without edges) to avoid slippery effects and lower surface is plain.

Dimensions: Sizes are 1mtr x 2mtr or long length and thickness as per classification & designation

Working Temp: -10 to 55°C

Typical Features:

  • Confirming IS: 15652/2006 (Latest), ISI marked.
  • High Die Electric Strength Up to 65 KV.
  • Insulation Resistance Up to 1494000 Mega Ohm.
  • Fire Retardant.
  • Good Mechanical Properties to with Stand Load and Movement of Breaker Trolleys and Associated Electrical Equipment including heavy foot traffic.
  • No Adverse Effect of Acids, Alkalis and Transformer Oil.
  • Manufactured Without Any Metallic Derivatives
  • Suitable For Both A.C & D.C Electrical Installations
  • Easy To Install, Can Be Pasted.
  • Water And Moisture Proof, Does Not Decay.
  • High Tensile Strength and Elongation Properties.

Application:

Safety from electrical shock is required for workmen whether they are involved in electricity generation, transmission, distribution or its use. These mats are highly recommended for total safety of workmen from electrical shock when working in or around environment like:

  • High Voltage Panels
  • Sub-station
  • Power Transformer Rooms
  • LT & HT Labs
  • Near Bus bars
  • Near Control Panels etc.

Insulation Mat Is 15652

Request Callback

₹ 100 / Meter Get Latest Price

Product Brochure
Thickness2.5 mm
Voltage11 KV
MaterialPVC
Size1 Meter X 10 Meter
Usage/ApplicationFlooring
Country of OriginMade in India

Minimum order quantity: 1 Meter

Item Code: IS-15652-2006

Voltage Ratings:


  • Class Thickness Grade KV Proof voltage B/Down voltage
  • A 2.0 mm 3.3 10KV/3 minutes 30 KV
  • B 2.5 mm 11 22KV/3 minutes 45 KV
  • C 3.0 mm 33 36KV/3 minutes 65 KV

Construction:

Made from Highly Electrical resistant Elastomers, free from any insertions (includes rubbers, latex and Elastomeric compound that may be natural or synthetic or a mixture or a combination of both)

Surface: Upper surface of the mat is having small anti-skid aberration marks (rough surface, without edges) to avoid slippery effects and lower surface is plain.

Dimensions: Sizes are 1mtr x 2mtr or long length and thickness as per classification & designation

Working Temp: -10 to 55°C

Typical Features:

  • Confirming IS: 15652/2006 (Latest), ISI marked.
  • High Die Electric Strength Up to 65 KV.
  • Insulation Resistance Up to 1494000 Mega Ohm.
  • Fire Retardant.
  • Good Mechanical Properties to with Stand Load and Movement of Breaker Trolleys and Associated Electrical Equipment including heavy foot traffic.
  • No Adverse Effect of Acids, Alkalis and Transformer Oil.
  • Manufactured Without Any Metallic Derivatives
  • Suitable For Both A.C & D.C Electrical Installations
  • Easy To Install, Can Be Pasted.
  • Water And Moisture Proof, Does Not Decay.
  • High Tensile Strength and Elongation Properties.

Application:

Safety from electrical shock is required for workmen whether they are involved in electricity generation, transmission, distribution or its use. These mats are highly recommended for total safety of workmen from electrical shock when working in or around environment like:

  • High Voltage Panels
  • Sub-station
  • Power Transformer Rooms
  • LT & HT Labs
  • Near Bus bars
  • Near Control Panels etc.

Checkered Mat Rubber

Request Callback

₹ 700 / Piece Get Latest Price

Product Brochure
Thickness25 mm
Size3x4 ft
Item Code: IS-15652-2006

Voltage Ratings:


  • Class Thickness Grade KV Proof voltage B/Down voltage
  • A 2.0 mm 3.3 10KV/3 minutes 30 KV
  • B 2.5 mm 11 22KV/3 minutes 45 KV
  • C 3.0 mm 33 36KV/3 minutes 65 KV

Construction:

Made from Highly Electrical resistant Elastomers, free from any insertions (includes rubbers, latex and Elastomeric compound that may be natural or synthetic or a mixture or a combination of both)

Surface: Upper surface of the mat is having small anti-skid aberration marks (rough surface, without edges) to avoid slippery effects and lower surface is plain.

Dimensions: Sizes are 1mtr x 2mtr or long length and thickness as per classification & designation

Working Temp: -10 to 55°C

Typical Features:

  • Confirming IS: 15652/2006 (Latest), ISI marked.
  • High Die Electric Strength Up to 65 KV.
  • Insulation Resistance Up to 1494000 Mega Ohm.
  • Fire Retardant.
  • Good Mechanical Properties to with Stand Load and Movement of Breaker Trolleys and Associated Electrical Equipment including heavy foot traffic.
  • No Adverse Effect of Acids, Alkalis and Transformer Oil.
  • Manufactured Without Any Metallic Derivatives
  • Suitable For Both A.C & D.C Electrical Installations
  • Easy To Install, Can Be Pasted.
  • Water And Moisture Proof, Does Not Decay.
  • High Tensile Strength and Elongation Properties.

Application:

Safety from electrical shock is required for workmen whether they are involved in electricity generation, transmission, distribution or its use. These mats are highly recommended for total safety of workmen from electrical shock when working in or around environment like:

  • High Voltage Panels
  • Sub-station
  • Power Transformer Rooms
  • LT & HT Labs
  • Near Bus bars
  • Near Control Panels etc.

Electrical Rubber Mats Is 5424 33kv Isi

Request Callback

₹ 450 / Meter Get Latest Price

Product Brochure
Thickness3mm
ColorRed
PatternCheckered
MaterialPVC
Country of OriginMade in India

Minimum order quantity: 2 Meter

Item Code: IS-15652-2006

Voltage Ratings:


  • Class Thickness Grade KV Proof voltage B/Down voltage
  • A 2.0 mm 3.3 10KV/3 minutes 30 KV
  • B 2.5 mm 11 22KV/3 minutes 45 KV
  • C 3.0 mm 33 36KV/3 minutes 65 KV

Construction:

Made from Highly Electrical resistant Elastomers, free from any insertions (includes rubbers, latex and Elastomeric compound that may be natural or synthetic or a mixture or a combination of both)

Surface: Upper surface of the mat is having small anti-skid aberration marks (rough surface, without edges) to avoid slippery effects and lower surface is plain.

Dimensions: Sizes are 1mtr x 2mtr or long length and thickness as per classification & designation

Working Temp: -10 to 55°C

Typical Features:

  • Confirming IS: 15652/2006 (Latest), ISI marked.
  • High Die Electric Strength Up to 65 KV.
  • Insulation Resistance Up to 1494000 Mega Ohm.
  • Fire Retardant.
  • Good Mechanical Properties to with Stand Load and Movement of Breaker Trolleys and Associated Electrical Equipment including heavy foot traffic.
  • No Adverse Effect of Acids, Alkalis and Transformer Oil.
  • Manufactured Without Any Metallic Derivatives
  • Suitable For Both A.C & D.C Electrical Installations
  • Easy To Install, Can Be Pasted.
  • Water And Moisture Proof, Does Not Decay.
  • High Tensile Strength and Elongation Properties.

Application:

Safety from electrical shock is required for workmen whether they are involved in electricity generation, transmission, distribution or its use. These mats are highly recommended for total safety of workmen from electrical shock when working in or around environment like:

  • High Voltage Panels
  • Sub-station
  • Power Transformer Rooms
  • LT & HT Labs
  • Near Bus bars
  • Near Control Panels etc.

Astm D 178 Electrical Mat

Request Callback

₹ 1100 / Meter Get Latest Price

Product Brochure
Thickness4mm
ColorBlack
PatternCheckered
Country of OriginMade in India

Minimum order quantity: 1 Meter

We deliver rubber insulating mattings that are designed according to the ASTM-D-178 Standard. This standard is set by the American Society for Testing and Materials. The ASTM-D-178 Standard endorses a thickness of 3.2mm to 12.7mm for these particular mattings. It depends upon the smooth lower surface with the usage/working voltage resistance & antiskid textured surface on the top. Such safety rubber mattings (Type-1 Grade) are moisture, water & leakage proof that guarantee a long functional (work) life. A Type-2 Grade Insulating Mat contains certain additional properties such as Flame & Ozone resistance.

 

 

Product Code

Class

Recommended Thickness

Max Use/Working Voltage

AC Proof Voltage

Di-electric strength (Withstand Voltage)

Approx. Weight Per Sqr Mtr.

ASTM 001

0

3.2 mm

1.0 KV

5.0 KV

6.0 KV

5.0 Kgs

ASTM 002

1

4.8 mm

7.5 KV

10.0 KV

20.0 KV

7.5 Kgs

ASTM 003

2

6.4 mm

17.0 KV

20.0 KV

30.0 KV

10.0 Kgs

ASTM 004

3

9.5 mm

26.5 KV

30.0 KV

40.0 KV

15.0 Kgs

ASTM 005

4

12.7 mm

36.0 KV

40.0 KV

50.0 KV

20.0 Kgs

ASTM CD (Custom)

-

Upto 25.0 mm

Upto 36.0 KV

Upto 40.0 KV

Upto 50.0 KV

-

 

Sl No.

Features

Values

1

Standard Size & Design

1) 1.0 Mtr. Wide x 10.0 Mtr. Long. in Texture Design.

2) 1.2 Mtr. Wide x 10.0 Mtr. Long. in Texture Design

2

Custom Size & Design

Max. width upto 2400mm, length upto 20M and thickness upto 25mm available in Texture Design only

3

Standard Colour

Black & Blue without Metallic Derivatives. (Other colours available on request subject to availability.)

4

Manufacturing Tolerance

±10% on thickness, ±5% on length, ±2% on width

5

Type

Unless specified, insulating matting shall be supplied as per Type I grade. Also available on request, Type II grade (A-Ozone Resistance, B-Flame Resistance, C-Oil Resistance) with combination of all three or individual properties.

 

Standard Size & Design

1.0 Mtr Wide x 10.0 Mtr Long in Textured Design

Standard Colour

Black & Blue without Metallic Derivatives (Other colours available on request subject to availability)

ASTM D Electrical Insulation Mat

Request Callback

₹ 900 / Meter Get Latest Price

Product Brochure
Thickness10 mm
Voltage33 KV
MaterialRubber

Minimum order quantity: 1 Meter

We deliver rubber insulating mattings that are designed according to the ASTM-D-178 Standard. This standard is set by the American Society for Testing and Materials. The ASTM-D-178 Standard endorses a thickness of 3.2mm to 12.7mm for these particular mattings. It depends upon the smooth lower surface with the usage/working voltage resistance & antiskid textured surface on the top. Such safety rubber mattings (Type-1 Grade) are moisture, water & leakage proof that guarantee a long functional (work) life. A Type-2 Grade Insulating Mat contains certain additional properties such as Flame & Ozone resistance.

 

 

Product Code

Class

Recommended Thickness

Max Use/Working Voltage

AC Proof Voltage

Di-electric strength (Withstand Voltage)

Approx. Weight Per Sqr Mtr.

ASTM 001

0

3.2 mm

1.0 KV

5.0 KV

6.0 KV

5.0 Kgs

ASTM 002

1

4.8 mm

7.5 KV

10.0 KV

20.0 KV

7.5 Kgs

ASTM 003

2

6.4 mm

17.0 KV

20.0 KV

30.0 KV

10.0 Kgs

ASTM 004

3

9.5 mm

26.5 KV

30.0 KV

40.0 KV

15.0 Kgs

ASTM 005

4

12.7 mm

36.0 KV

40.0 KV

50.0 KV

20.0 Kgs

ASTM CD (Custom)

-

Upto 25.0 mm

Upto 36.0 KV

Upto 40.0 KV

Upto 50.0 KV

-

 

Sl No.

Features

Values

1

Standard Size & Design

1) 1.0 Mtr. Wide x 10.0 Mtr. Long. in Texture Design.

2) 1.2 Mtr. Wide x 10.0 Mtr. Long. in Texture Design

2

Custom Size & Design

Max. width upto 2400mm, length upto 20M and thickness upto 25mm available in Texture Design only

3

Standard Colour

Black & Blue without Metallic Derivatives. (Other colours available on request subject to availability.)

4

Manufacturing Tolerance

±10% on thickness, ±5% on length, ±2% on width

5

Type

Unless specified, insulating matting shall be supplied as per Type I grade. Also available on request, Type II grade (A-Ozone Resistance, B-Flame Resistance, C-Oil Resistance) with combination of all three or individual properties.

 

Standard Size & Design

1.0 Mtr Wide x 10.0 Mtr Long in Textured Design

Standard Colour

Black & Blue without Metallic Derivatives (Other colours available on request subject to availability)

IEC Mats

Request Callback

₹ 850 / Meter Get Latest Price

Product Brochure
Thickness4mm
Voltage11 KV
MaterialRubber
Size1 Meter X 10 Meter
ColorBlack / Grey
Usage/ApplicationElectrical
Country of OriginMade in India

Minimum order quantity: 1 Meter

Insulating Matting (Di-Electric Carpets) made of Rubber Compound suitable for providing the Electrical safety to the workmen working around the possible areas of Electrical shock and act as a safeguard equipment from electrical shock due to leakage of current, shot circuit or any other. The special high quality Rubber Compound ensures the complete shock protection against electrical shocks due to electrical earth faults.

Our Mats are fully compliant With IEC 61111 (International Electro Technical Commission) and are regularly tested by third like TUV, Lloyds and many others. The mats offered by us are ROHS and PAH Compliant.

Features And Advantages
  • Fully tested to specification IEC 61111.
  • Provides safety for operators against electrical shock.
  • High Electrical Resistance Up to 50 KV/50000 volts.
  • Suitable for both AC and DC Applications.
  • Health and safety regulation Halogen Free flame retardant material.
  • Highly Flexible mats with self-gripping design on floor.
  • Anti-Fatigue type. Comfortable while standing for long period.
  • Anti-Slip Finish. Tested to slip resist test.
  • Resistant to acid, oil and Low temperature test.
  • Ozone, UV and weather resistant.
  • Permanent Marking-Durable and un-erasable done while curing of mats.
  • Fully Traceable supply.
  • Low Maintainance.
  • No Recycled Rubber.
ClassStandard ThicknessMax. Use VoltageProof VoltageWithstand VoltageColor Code
0 3 mm 1000 Volts 5000 Volts 10000 Volts Red
1 3 mm 7500 Volts 10000 Volts 20000 Volts White
2 3/6 mm 17000 Volts 20000 Volts 30000 Volts Yellow
3 4/6 mm 26500 Volts 30000 Volts 40000 Volts Green
4 4/6 mm 36000 Volts 40000 Volts 50000 Volts Orange

 

Dimensions
Width 0.9mtr, 1.0mtr, 1.2mtr
Length 2mtr, 5mtr, 10mtr, 20mtr, or as per requirement
Thickness As Per Specified Class
Colors Black, Blue, Grey
Surface/Design Anti-Skid Texture Finish

Note: Other colors also available on request.

Other Properties
S.No.Technical SpecificationAll Classes
1 Composition and Surface Rubber elastomer*, Anti Skid Finish. Macromolecular material which returns rapidly to its final dimension by a weak stress and release of the stress.
2 Workmanship Mats shall be free from Harmful physical irregularities.
3 Mechanical Puncture Resistance Min. 70N
4 Slip Resistance Test @ force of 70N Maximum 15mm
5 Ageing Test at 70 deg cl./168hrs. Puncture Resistance shall be min. 80% of original value.
6 Flame Retardant Test Flame shall not reach any point on a 50mm circle.
7 Thermal Test (Low Temp. Test) No Crack@100N.
No-Breakdown on specified voltage.
8 Acid Test; H2SO4 For 8hrs. Minimum Retention in Mech. Puncture Test initial value. Min. 75% Retention & No Breakdown on specified Voltage.
9 Oil Test; oil for 2hrs.
Minimum Retention in Mech. Puncture test initial value.
Min. 75% Retention & No Breakdown on specified Voltage.

Astm D 178 Electrical Insulation Mat

Request Callback

₹ 1200 / Meter Get Latest Price

Product Brochure
Thickness8 mm
Voltage11 KV
MaterialRubber
Size1 Meter x 10 Meter
ColorBlack / Grey
Country of OriginMade in India

Minimum order quantity: 1 Meter

We deliver rubber insulating mattings that are designed according to the ASTM-D-178 Standard. This standard is set by the American Society for Testing and Materials. The ASTM-D-178 Standard endorses a thickness of 3.2mm to 12.7mm for these particular mattings. It depends upon the smooth lower surface with the usage/working voltage resistance & antiskid textured surface on the top. Such safety rubber mattings (Type-1 Grade) are moisture, water & leakage proof that guarantee a long functional (work) life. A Type-2 Grade Insulating Mat contains certain additional properties such as Flame & Ozone resistance.

 

 

Product Code

Class

Recommended Thickness

Max Use/Working Voltage

AC Proof Voltage

Di-electric strength (Withstand Voltage)

Approx. Weight Per Sqr Mtr.

ASTM 001

0

3.2 mm

1.0 KV

5.0 KV

6.0 KV

5.0 Kgs

ASTM 002

1

4.8 mm

7.5 KV

10.0 KV

20.0 KV

7.5 Kgs

ASTM 003

2

6.4 mm

17.0 KV

20.0 KV

30.0 KV

10.0 Kgs

ASTM 004

3

9.5 mm

26.5 KV

30.0 KV

40.0 KV

15.0 Kgs

ASTM 005

4

12.7 mm

36.0 KV

40.0 KV

50.0 KV

20.0 Kgs

ASTM CD (Custom)

-

Upto 25.0 mm

Upto 36.0 KV

Upto 40.0 KV

Upto 50.0 KV

-

 

Sl No.

Features

Values

1

Standard Size & Design

1) 1.0 Mtr. Wide x 10.0 Mtr. Long. in Texture Design.

2) 1.2 Mtr. Wide x 10.0 Mtr. Long. in Texture Design

2

Custom Size & Design

Max. width upto 2400mm, length upto 20M and thickness upto 25mm available in Texture Design only

3

Standard Colour

Black & Blue without Metallic Derivatives. (Other colours available on request subject to availability.)

4

Manufacturing Tolerance

±10% on thickness, ±5% on length, ±2% on width

5

Type

Unless specified, insulating matting shall be supplied as per Type I grade. Also available on request, Type II grade (A-Ozone Resistance, B-Flame Resistance, C-Oil Resistance) with combination of all three or individual properties.

 

Standard Size & Design

1.0 Mtr Wide x 10.0 Mtr Long in Textured Design

Standard Colour

Black & Blue without Metallic Derivatives (Other colours available on request subject to availability)

Electric Shock Proof Rubber Mat

Request Callback

₹ 100 / Meter Get Latest Price

Product Brochure
Mat Size1 Meter X 10 Meter
Item Code: IS-15652-2006

Voltage Ratings:


  • Class Thickness Grade KV Proof voltage B/Down voltage
  • A 2.0 mm 3.3 10KV/3 minutes 30 KV
  • B 2.5 mm 11 22KV/3 minutes 45 KV
  • C 3.0 mm 33 36KV/3 minutes 65 KV

Construction:

Made from Highly Electrical resistant Elastomers, free from any insertions (includes rubbers, latex and Elastomeric compound that may be natural or synthetic or a mixture or a combination of both)

Surface: Upper surface of the mat is having small anti-skid aberration marks (rough surface, without edges) to avoid slippery effects and lower surface is plain.

Dimensions: Sizes are 1mtr x 2mtr or long length and thickness as per classification & designation

Working Temp: -10 to 55°C

Typical Features:

  • Confirming IS: 15652/2006 (Latest), ISI marked.
  • High Die Electric Strength Up to 65 KV.
  • Insulation Resistance Up to 1494000 Mega Ohm.
  • Fire Retardant.
  • Good Mechanical Properties to with Stand Load and Movement of Breaker Trolleys and Associated Electrical Equipment including heavy foot traffic.
  • No Adverse Effect of Acids, Alkalis and Transformer Oil.
  • Manufactured Without Any Metallic Derivatives
  • Suitable For Both A.C & D.C Electrical Installations
  • Easy To Install, Can Be Pasted.
  • Water And Moisture Proof, Does Not Decay.
  • High Tensile Strength and Elongation Properties.

Application:

Safety from electrical shock is required for workmen whether they are involved in electricity generation, transmission, distribution or its use. These mats are highly recommended for total safety of workmen from electrical shock when working in or around environment like:

  • High Voltage Panels
  • Sub-station
  • Power Transformer Rooms
  • LT & HT Labs
  • Near Bus bars
  • Near Control Panels etc.
X

Contact Us

Aditya Mandelia (CEO)
Mandelia Insulation & Transmission Co.
C-13, Way To Hill Top, RIICO Chowk
Bhiwadi - 301019, Alwar, Rajasthan, India

Get Directions
Send Email
Share: